{"product_id":"replacement-mini-oxidiser-cell","title":"Replacement MINI Oxidiser Cell","description":"\u003cp\u003e\u003cspan class=\"prodConsumableFamily\"\u003eSuitable for NKD-M System Only\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"prodDesc\"\u003e\n\u003cp\u003eReplacement NKD-M Oxidiser Cell with lead and connector plug. Suitable for Naked MINI only.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIncludes \u003c\/span\u003e\u003cstrong\u003eFREE\u003c\/strong\u003e\u003cspan\u003e Shipping anywhere in Australia.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNKD-M Oxidiser Cell (complete with lead and plug)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cheader class=\"article-header\"\u003e\n\u003ch1 title=\"Inspecting and cleaning the OXI Cell\" class=\"article-title\"\u003eInspecting and cleaning the OXI Cell\u003c\/h1\u003e\n\u003cdiv class=\"article-author\"\u003e\n\u003cdiv class=\"article-meta\"\u003e\n\u003cul class=\"meta-group\"\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/header\u003e\n\u003csection class=\"article-info\"\u003e\n\u003cdiv class=\"article-content\"\u003e\n\u003cdiv class=\"article-body\"\u003e\n\u003cp class=\"p1\"\u003eReverse Polarity electrodes should not normally require cleaning, however, in areas with very hard water all calcium may not be removed. A calcium deposit might form on the lower areas of the electrode, the sensor or the sides of the electrode plates. This will\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNOT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaffect the operation of your system. Monitoring\u003cspan\u003e \u003c\/span\u003epH\u003cspan\u003e \u003c\/span\u003elevels weekly\/fortnightly and maintaining them within range will assist in less calcium build up.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eAll electrodes must be cleaned before scale\/calcium builds up to the point where the electrode gaps in the OXI Cell become bridged. If the OXI Cell has\u003cspan\u003e \u003c\/span\u003eexcessive calcium deposit, this may damage the electrode coating, as the bridging on the plates affects operation. The OXI OUT % can also decrease due to excessive build up of calcium and once cleaned will return to normal levels.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eCheck the OXI Cell to prevent the accumulation of pool debris that for any reason may have by-passed the pool filter, particularly after backwashing.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eCheck that the O-ring is clean, greased with silicone grease (\u003cstrong\u003eDO NOT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euse petroleum based jelly) and securely located in the Housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"p1\" id=\"h_01K1YWMM90E5XWVD9519H58MBY\"\u003eFor cleaning, please follow these steps:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eSwitch off the wall outlet switch as this ensures the pump and system will not turn on.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eUnscrew the OXI Cell Locking Ring and remove the electrode for inspection. If calcium build-up is present, immerse the electrode in a cell cleaning solution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003eA solution can be made by mixing 1 part hydrochloric acid to 10 parts of water. If excessive build up is present a stronger solution may be used to remove the calcium. Using 5 parts of water will make a more aggressive solution and will not damage the electrode. You can use cell cleaning solutions and if you do then follow the instructions supplied. Allow the cleaning solution to dissolve the calcium deposits for about 10 minutes. Dispose of the cleaning solution at an approved Council Depot and never into storm water or sewage drains.\u003c\/p\u003e\n\u003ch3 class=\"p1\" id=\"h_01K1YWMM915GSH90YHCDSVHFK1\"\u003eHandy Tip:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eReturning this mix to your pool only returns the calcium you just removed, so you may be better off reusing the solution until exhausted then disposing of it. Always store this solution safely as advised on the container.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eDo not scratch or bend the electrode plates in the Housing.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eEnsure that the O-ring is clean, greased and properly seated.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eRinse the electrode in clean water and re-fit the electrode in the Housing, ensuring that the cell plates are in a vertical orientation and the locating tab on the cell head is correctly inserted into the groove on the cell housing and the Locking Ring is hand tight and secure.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eTurn on the wall outlet switch and the pump and the system will return to the mode it was in before.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"p1\" id=\"h_01K1YWMM916QXH4585FCJGF5EW\"\u003eImportant:\u003c\/h3\u003e\n\u003cp class=\"p1\"\u003eWhen mixing acid with water,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eALWAYS ADD ACID TO WATER. NEVER ADD WATER TO ACID\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eEye Protection, mask and gloves should be worn when cleaning the cell.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Eclipse Pool Products","offers":[{"title":"Default Title","offer_id":44811213701171,"sku":"NKD-M Oxidiser Cell","price":1150.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0619\/6635\/2435\/files\/product-11-250910-062921.jpg?v=1788312470","url":"https:\/\/www.poolandspaaccessories.com.au\/products\/replacement-mini-oxidiser-cell","provider":"Pool and Spa Accessories","version":"1.0","type":"link"}