{"product_id":"asp-peristaltic-pump-service-kit","title":"ASP Peristaltic Pump Service Kit","description":"\u003cp\u003e\u003cspan\u003eChemical delivery service kit for Pool Lab Auto Sampling Photometer (ASP).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePureSilk CPS2 Peristaltic Pump Service Kit\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e55619 – PERISTALTIC PUMP SERVICE KIT\u003c\/h1\u003e\n\u003cp\u003eTo suit Pool Lab ASP (Auto Sampling Photometer) and Pool Lab Hybrid Systems\u003cbr\u003efor both acid and liquid chlorine feed peristaltic pumps. Replace every 12 months.\u003cspan\u003e\u003ca href=\"https:\/\/www.poolpower.com.au\/page\/13\/marketing-videos#peripump-service\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKit Contains:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDrum Cap -\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAssembled with tubing and weights\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS0xLnBuZyIsImVkaXRzIjp7InJlc2l6ZSI6eyJ3aWR0aCI6NDE5LCJoZWlnaHQiOjE5NywiZml0IjoiaW5zaWRlIn19LCJ2ZXJzaW9uIjoiIn0=\" alt=\"\" width=\"419\" height=\"197\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePump Tube \u0026amp; Roller Kit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS0yLnBuZyIsImVkaXRzIjp7InJlc2l6ZSI6eyJ3aWR0aCI6Mjc1LCJoZWlnaHQiOjIxMCwiZml0IjoiaW5zaWRlIn19LCJ2ZXJzaW9uIjoiIn0=\" alt=\"\" width=\"275\" height=\"210\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInjector Valve\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS0zLnBuZyIsImVkaXRzIjp7InJlc2l6ZSI6eyJ3aWR0aCI6MjI5LCJoZWlnaHQiOjExNywiZml0IjoiaW5zaWRlIn19LCJ2ZXJzaW9uIjoiIn0=\" alt=\"\" width=\"229\" height=\"117\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5g Silicone Lube\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS00LnBuZyIsImVkaXRzIjp7InJlc2l6ZSI6eyJ3aWR0aCI6MTMyLCJoZWlnaHQiOjE2MCwiZml0IjoiaW5zaWRlIn19LCJ2ZXJzaW9uIjoiIn0=\" alt=\"\" width=\"132\" height=\"160\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eREAD THIS BEFORE SERVICING\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eALWAYS WEAR SAFETY GOGGLES AND GLOVES WHEN SERVICING THE PERISTALTIC PUMP AND\/OR CHEMICAL FEED LINES\u003c\/li\u003e\n\u003cli\u003eUSE A TYPE E RESPIRATOR TO PROTECT AIRWAYS FROM ACID FUMES\u003c\/li\u003e\n\u003cli\u003eUSE OF ACID RESISTANT BOOTS IS RECOMMENDED\u003c\/li\u003e\n\u003cli\u003eIT IS ADVISED (WHERE POSSIBLE) TO FLUSH THE CHEMICAL LINES WITH FRESH WATER BEFORE SERVICING TO REDUCE THE CHANCE OF SPILLIAGE\u003c\/li\u003e\n\u003cli\u003eALWAYS ENSURE THERE IS PLENTY OF FRESH WATER READILY AVAILABLE TO RINSE ANY SPILLED CHEMICALS, OR TOOLS \/ CLOTHING \/ SKIN \/ EYES ETC. EXPOSED TO CHEMICALS\u003c\/li\u003e\n\u003cli\u003eTHE POOL LAB PERISTALTIC PUMP HAS BEEN DESIGNED FOR USE WITH 16.5% HYDROCHLORIC ACID ONLY. USE OF HIGHER STRENGTH HYDROCHLORIC ACID (OR OTHER ACID TYPES) MAY DAMAGE EQUIPMENT, AND RESULT IN A SAFETY HAZARD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eWARNING: Extreme care must be taken when working with the acid feed tubing as under certain\u003c\/em\u003e\u003cbr\u003e\u003cem\u003econditions the tubing may be pressurized. Loosen the acid drum reservoir cap to relieve any potential\u003c\/em\u003e\u003cbr\u003e\u003cem\u003epressure on the inlet. If acid injection point is below water level, ensure appropriate isolation valves\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eare closed and vent isolated plumbing section to relieve any pressure before proceeding.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS01LnBuZyIsImVkaXRzIjp7InJlc2l6ZSI6eyJ3aWR0aCI6MTA5OCwiaGVpZ2h0IjoxNTksImZpdCI6Imluc2lkZSJ9fSwidmVyc2lvbiI6IiJ9\" alt=\"\" width=\"1098\" height=\"159\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHydrochloric (Muriatic) Acid Warnings\u003c\/strong\u003e\u003c\/span\u003e\u003cem\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e➔ Read warnings on the label. Do not allow acid to come in contact with skin, eyes or mouth, and follow directions on label if accidental contact occurs.\u003c\/li\u003e\n\u003cli\u003e➔ Hydrochloric acid is highly corrosive, and will corrode metallic surfaces.\u003c\/li\u003e\n\u003cli\u003e➔ General advice for accidental contact with Hydrochloric Acid is to flush with fresh cold water for at least 15 minutes, and remove any contaminated clothing. Seek immediate medical attention.\u003c\/li\u003e\n\u003cli\u003e➔ Hydrochloric Acid does produce dangerous fumes. These fumes are highly irritant to skin, eyes and airways, and can also damage equipment. Always ensure the area is well ventilated when handling acid.\u003c\/li\u003e\n\u003cli\u003e➔ Always wear protective clothing when handling acid or servicing the acid dosing system. Acid resistant gloves, eye protection or face shield, boots and a suitable respirator are recommended.\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eNote: a Type E filter approved to EN141, European Standard for Gas Filters is suitable for Hydrochloric acid fumes.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e➔ Service acid dosing pump at least every 12 months.\u003c\/li\u003e\n\u003cli\u003e➔ When diluting acid, always add acid to water. \u003cstrong\u003eNever add water to acid.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e➔ Store acid in a cool, dry, and well ventilated place away from sources of moisture. Keep away from incompatible materials, such as oxidizing agents, organic materials, metals and alkalis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAcid Dosing System Warnings\u003c\/strong\u003e\u003c\/span\u003e\u003cem\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e➔ For installations where an acid leak could result in damage to property such as flooring or nearby equipment, or where a leak may result in a safety hazard, the drum must be located within an additional containment vessel with a capacity no less than 200% of the acid drum volume. The containment vessel must be made from a plastic suitable for containment of hydrochloric acid eg. High Density Polyethylene (aka. HDPE) and should ideally be located directly below the acid pump and feed tubes so that it may catch any potential leaks from acid feed tubing and fittings. This will minimize the risk in the event of a leak.\u003c\/li\u003e\n\u003cli\u003e➔ The area around the acid dosing system, including the storage drum and feed tubes must be inaccessible to children, animals and other unauthorised persons.\u003c\/li\u003e\n\u003cli\u003e➔ The acid drum MUST NOT BE located in direct sunlight as heat will cause the drum to pressurize, resulting in a safety hazard and increased risk of leakage.\u003c\/li\u003e\n\u003cli\u003e➔ Where a SPA ONLY system exist, acid drum volume must be limited to 5 Litres.\u003c\/li\u003e\n\u003cli\u003e➔ The acid drum and acid dosing system components must be located in a well ventilated area (preferably a shaded outdoor area) where there is minimal risk of damage to persons and\/or property in the event of an acid leak.\u003c\/li\u003e\n\u003cli\u003e➔ For indoor installations the installer must complete a risk assessment and discuss plans with the property owner for minimizing risks to persons and property.\u003c\/li\u003e\n\u003cli\u003e➔ All elements of the acid dosing system must be regularly inspected to ensure it is in safe working order. Component must be replaced as per the instructions if degradation is evident.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003ePoolpower Australia Pty. Ltd. will not be liable for damage where a duty of care has not been demonstrated with respect to the installation of this equipment or its ongoing maintenance.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan\u003ePeristaltic Pump Service Procedure\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStep 1: Flush the feed pump and tubing with fresh water.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe filtration system must be running to perform this task. Change filtration mode to \u003cstrong\u003eON\u003c\/strong\u003e if required, and use the A\u003cstrong\u003eCID PRIME\u003c\/strong\u003e or \u003cstrong\u003eLCHL PRIME\u003c\/strong\u003e function in the \u003cstrong\u003eASP TOOLS\u003c\/strong\u003e menu to flush water through the tubing.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS02LnBuZyIsImVkaXRzIjp7InJlc2l6ZSI6eyJ3aWR0aCI6MTI0LCJoZWlnaHQiOjE4NywiZml0IjoiaW5zaWRlIn19LCJ2ZXJzaW9uIjoiIn0=\" alt=\"\" width=\"124\" height=\"187\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea) Loosen the fume stop cap to relieve any pressure in the drum\u003c\/li\u003e\n\u003cli\u003eb) Remove the drum cap, and place end of feed line into a bucket of fresh water\u003c\/li\u003e\n\u003cli\u003ec) On the chlorinator control panel, press and hold \u003cstrong\u003eVIEW\u003c\/strong\u003e until the MAIN MENU appears\u003c\/li\u003e\n\u003cli\u003ed) Navigate to \u003cstrong\u003eASP TOOLS\u003c\/strong\u003e and press \u003cstrong\u003eVIEW\u003c\/strong\u003e (ASP TOOLS menu appears)\u003c\/li\u003e\n\u003cli\u003ee) Navigate to \u003cstrong\u003eACID\/LCHL PRIME\u003c\/strong\u003e and press \u003cstrong\u003eVIEW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ef) Press \u003cstrong\u003eVIEW\u003c\/strong\u003e to start the feed pump (60 second timer)\u003c\/li\u003e\n\u003cli\u003eg) Allow PRIME to finish, and repeat\u003c\/li\u003e\n\u003cli\u003eh) Press \u003cstrong\u003eBACK\u003c\/strong\u003e button at least 3 times to return to the HOME VIEW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This procedure is never guaranteed to flush all chemicals from the system, especially if the pump has not been performing well. Always wear appropriate protective clothing and proceed with caution when handling liquid chlorine and\/or acid while servicing the dosing system.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStep 2: Prepare the system for servicing.\u003c\/strong\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eTurn OFF and disconnect the filtration pump. Relieve the plumbing of any pressure or vacuum. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea) Change the FILTRATION MODE to \u003cstrong\u003eOFF\u003c\/strong\u003e using the \u003cstrong\u003eMODE\u003c\/strong\u003e button\u003c\/li\u003e\n\u003cli\u003eb) Disconnect the filtration pump power cord to prevent accidental start up\u003c\/li\u003e\n\u003cli\u003ec) If the acid injection point is below water, close both suction and return isolation valves\u003c\/li\u003e\n\u003cli\u003ed) Relieve any pressure or vacuum from the plumbing section that has the injection point, and drain enough water from the plumbing system so that the injection point is above the water level*\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e* The procedure for (d) depends on your system components and configuration\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e Step 3: Remove the old squeeze tube and rollers. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea) Loosen and remove both lock nuts securing feed tubing to the pump, and disconnect both feed tubes\u003c\/li\u003e\n\u003cli\u003eb) Remove 2x screws (1, 2) securing the clear plastic outer cover (3), and remove cover\u003c\/li\u003e\n\u003cli\u003ec) Remove old squeeze tube (10) and discard\u003c\/li\u003e\n\u003cli\u003ed) Remove outer rotor half (4) and discard\u003c\/li\u003e\n\u003cli\u003ee) Remove 4 x rollers (5,6,7,8) and discard\u003c\/li\u003e\n\u003cli\u003ef) Remove inner rotor half (9) - this may require a flat head screw driver or similar as a lever\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS03LnBuZyIsImVkaXRzIjp7InJlc2l6ZSI6eyJ3aWR0aCI6NzkzLCJoZWlnaHQiOjM5OSwiZml0IjoiaW5zaWRlIn19LCJ2ZXJzaW9uIjoiIn0=\" alt=\"\" width=\"793\" height=\"399\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStep 4: Use a cloth to wipe clean the pump housing and cover to remove all the old grease.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStep 5:\u003c\/strong\u003e \u003cstrong\u003eInstall and lubricate new squeeze tube and roller parts.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS04LnBuZyIsImVkaXRzIjp7InJlc2l6ZSI6eyJ3aWR0aCI6Nzg4LCJoZWlnaHQiOjQxOSwiZml0IjoiaW5zaWRlIn19LCJ2ZXJzaW9uIjoiIn0=\" alt=\"\" width=\"788\" height=\"419\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLubricate the backing plate where it contacts the inner rotor half\u003c\/li\u003e\n\u003cli\u003eb) Install the inner rotor half (inner and outer rotor halves are identical parts)\u003c\/li\u003e\n\u003cli\u003ec) Add a small amount of lubricant to the inside running edge of each roller (ie. the hole)\u003c\/li\u003e\n\u003cli\u003ed) Install 4 x rollers. Ensure all 4 have the rounded edge facing outwards\u003c\/li\u003e\n\u003cli\u003ee) Install the outer rotor half, and add a small amount of lubricant to the outer face\u003c\/li\u003e\n\u003cli\u003ef) Lubricate rollers and squeeze lube liberally with silicone lubricant\u003c\/li\u003e\n\u003cli\u003eg) Install the squeeze tube - ensure tube connectors have the square lugs facing outwards\u003c\/li\u003e\n\u003cli\u003eh) Replace cover - position top edge in place first, then apply downward and inward force\u003c\/li\u003e\n\u003cli\u003ei) Replace 2 x screws to secure cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eWhen looking at the front of the pump, the inlet is on the left and the outlet is on the right. \u003c\/em\u003e\u003cem\u003eTighten lock nuts by hand only.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStep 6: Replace injector.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS05LnBuZyIsImVkaXRzIjp7InJlc2l6ZSI6eyJ3aWR0aCI6MzUzLCJoZWlnaHQiOjE5MSwiZml0IjoiaW5zaWRlIn19LCJ2ZXJzaW9uIjoiIn0=\" alt=\"\" width=\"353\" height=\"191\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea) Loosen and remove lock nut (1) securing tubing to injector, and disconnect tube\u003c\/li\u003e\n\u003cli\u003eb) Loosen and remove injector (2) - this may require a spanner if too tight\u003c\/li\u003e\n\u003cli\u003ec) Fit new injector, ensuring o-ring (3) is in place and tighten by hand only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStep 7:\u003c\/strong\u003e \u003cstrong\u003eReplace feed tubing.\u003c\/strong\u003e\u003c\/span\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea) Cut 2x lengths of new feed tubing as required:\u003c\/li\u003e\n\u003cli\u003e1 x for pump to injector connection\u003c\/li\u003e\n\u003cli\u003e1 x for pump to reservoir connection\u003c\/li\u003e\n\u003cli\u003eb) Connect tubing from pump outlet to injector, and tighten lock nuts by hand only\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eWhile tightening the injector lock nut, hold the injector body in place with a spanner to prevent over-tightening the cell housing thread\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003ec) Connect tubing to pump inlet and tighten lock nut\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS0xMC5wbmciLCJlZGl0cyI6eyJyZXNpemUiOnsid2lkdGgiOjc4MSwiaGVpZ2h0IjozNzAsImZpdCI6Imluc2lkZSJ9fSwidmVyc2lvbiI6IiJ9\" alt=\"\" width=\"781\" height=\"370\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStep 8:\u003c\/strong\u003e \u003cstrong\u003ePrepare the system for operation.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea) Check all pipe unions are tight\u003c\/li\u003e\n\u003cli\u003eb) Check both suction and return valves are open and positioned correctly\u003c\/li\u003e\n\u003cli\u003ec) Ensure the filtration mode is set to OFF, and reconnect filter pump power lead to the pump outlet socket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStep 9:\u003c\/strong\u003e \u003cstrong\u003eStart the system, and check for leaks.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea) Change filtration mode to ON using the MODE button\u003c\/li\u003e\n\u003cli\u003eb) Ensure water is flowing normally, and pressure gauges reading normal\u003c\/li\u003e\n\u003cli\u003ec) Check plumbing, feed tubing and connectors for any signs of leaks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStep 10:\u003c\/strong\u003e \u003cstrong\u003eTest pump operation with water, using the prime function.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea) Place the inlet end of the acid feed tube in a bucket of fresh water\u003c\/li\u003e\n\u003cli\u003eb) On the chlorinator control panel, press and hold VIEW until the MAIN MENU appears\u003c\/li\u003e\n\u003cli\u003ec) Navigate to ASP TOOLS and press VIEW (ASP TOOLS menu appears)\u003c\/li\u003e\n\u003cli\u003ed) Navigate to ACID\/LCHL PRIME and press VIEW\u003c\/li\u003e\n\u003cli\u003ee) Press VIEW to start the feed pump (60 second count down timer begins)\u003c\/li\u003e\n\u003cli\u003ef) Observe water being pumped along the feed tubes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStep 11:\u003c\/strong\u003e \u003cstrong\u003eFit fume stop cap back onto reservoir.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure the end of the feed tube can reach the bottom of the drum and adjust length if required.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/d1mv2b9v99cq0i.cloudfront.net\/eyJidWNrZXQiOiJ3ZWItbmluamEtaW1hZ2VzIiwia2V5IjoicG9vbHBvd2VyYjJiXC9jb250ZW50LWltYWdlXC9JbWFnZS0xMS5wbmciLCJlZGl0cyI6eyJyZXNpemUiOnsid2lkdGgiOjQ3NCwiaGVpZ2h0IjozMzIsImZpdCI6Imluc2lkZSJ9fSwidmVyc2lvbiI6IiJ9\" alt=\"\" width=\"474\" height=\"332\"\u003e\u003c\/p\u003e","brand":"Pool and Spa Accessories","offers":[{"title":"Default Title","offer_id":45330567528499,"sku":null,"price":145.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0619\/6635\/2435\/files\/PeristalticPumpServiceKit.png?v=1794443662","url":"https:\/\/www.poolandspaaccessories.com.au\/products\/asp-peristaltic-pump-service-kit","provider":"Pool and Spa Accessories","version":"1.0","type":"link"}